21 – 233 CFM Rated – “General Purpose” Filters

21 – 233 CFM Rated – “General Purpose” Filters

These General Purpose filters offer particle removal down to 1 micron including coalesced liquid, water and oil, providing a maximum remaining oil aerosol content of 0.5 mg/m 3 @ 21 degrees C.

Click to Download Brochure

Request a Quote: 847-678-8388

View Models & Specifications
IR filters come in four different series, G=General Purpose (1 micron/.5 ppm), H=High Efficiency (.01 micron /.01 ppm), A=Activated Carbon (.003 ppm), and D=Dust Protection (1 micron). G and H include auto float drains, while A and D have manual drains. All filters come with a differential pressure indicator. Ratings are based on 100F inlet air temperature and 100 PSIG inlet air pressure. Maximum pressure is 250 PSIG; ambient temperature is 35F-150F. Max temp for AC is 86F.

21 – 233 CFM Rated – “High Efficiency” Filters

21 – 233 CFM Rated – “High Efficiency” Filters

Ingersoll Rand "High Effeciency" filters offer particle removal down to 0.01 micron including water and oil aerosols, providing a maximum remaining oil aerosol content of 0.01 mg/m 3 @ 21 degrees C.

Click to Download Brochure

Request a Quote: 847-678-8388

View Models & Specifications
IR filters come in four different series, G=General Purpose (1 micron/.5 ppm), H=High Efficiency (.01 micron /.01 ppm), A=Activated Carbon (.003 ppm), and D=Dust Protection (1 micron). G and H include auto float drains, while A and D have manual drains. All filters come with a differential pressure indicator. Ratings are based on 100F inlet air temperature and 100 PSIG inlet air pressure. Maximum pressure is 250 PSIG; ambient temperature is 35F-150F. Max temp for AC is 86F.

21 – 233 CFM Rated – “Activated Carbon” Filters

21 – 233 CFM Rated – “Activated Carbon” Filters

Activated Carbon filter housings offer oil vapor and hydrocarbon odor removal, providing a maximum remaining oil content of <0.003 mg/m 3(<0.003 ppm) (excluding methane) @ 21 degrees C.

Click to Download Brochure

Request a Quote: 847-678-8388

View Models & Specifications
IR filters come in four different series, G=General Purpose (1 micron/.5 ppm), H=High Efficiency (.01 micron /.01 ppm), A=Activated Carbon (.003 ppm), and D=Dust Protection (1 micron). G and H include auto float drains, while A and D have manual drains. All filters come with a differential pressure indicator. Ratings are based on 100F inlet air temperature and 100 PSIG inlet air pressure. Maximum pressure is 250 PSIG; ambient temperature is 35F-150F. Max temp for AC is 86F.

21 – 233 CFM Rated – “Dust” Filters

21 – 233 CFM Rated – “Dust” Filters

Dust filters give you particle removal down to 1 micron. These housings are typically installed after the use of a desiccant type dryer to prevent any desiccant dust from being introduced downstream.

Click to Download Brochure

Request a Quote: 847-678-8388

View Models & Specifications
IR filters come in four different series, G=General Purpose (1 micron/.5 ppm), H=High Efficiency (.01 micron /.01 ppm), A=Activated Carbon (.003 ppm), and D=Dust Protection (1 micron). G and H include auto float drains, while A and D have manual drains. All filters come with a differential pressure indicator. Ratings are based on 100F inlet air temperature and 100 PSIG inlet air pressure. Maximum pressure is 250 PSIG; ambient temperature is 35F-150F. Max temp for AC is 86F.